Auto Transfer Switchgear (ATS)

  • Description
Product Detail

1. Overview

Auto transfer switchgear mainly consists of the auto transfer device which can be switched between the normal power supply and backup power supply to ensure reliability and continuity of power supply. It is widely applied in the important places which need uninterrupted power supply such as buildings, post, and telecommunication, mining enterprises and shipping

2. Technical parameters

Items

Parameters

Rated working voltage (V)

AC380

Rated  frequency

50

Rated  insulation voltage (V)

AC660

Auxiliary circuit insulation voltage (V)

AC380

 

Rated   impact withstand voltage Uimp(kV)

Main   circuit

8

Auxiliary   circuit

6

Overvoltage grade

?

Electric clearance

=8mm

Creepage distance

=10mm

Rated current of complete set equipment

400A

Main busbar rate current

400A

Rated short-time withstand current

10kA

Rated peak withstand current

17kA

Circuit number of power distribution(feeder) cabinet and control cabinet

4

Shell protection grade

IP30

Heat resistance grade

F

Rated current (Inc) and rated limited short-circuit current (Icc) of every outgoing circuit of power distribution(feeder) cabinet and control cabinet:

Circuit

Inc(A)

Icc(kA)

C1

160

10

C2

80

10

C3

80

10

C4

80

10

Rated current (Inc), rated limit short-circuit breaking capacity (Icu) and rated operation short-circuit breaking capacity(Ics) of every outgoing circuit of power distribution(feeder) cabinet and control cabinet:

Circuit

In(A)

Icu   (kA)           Ics(kA)

C1

200

Icu=35            Ics=25

C2

100

Icu=35            Ics=22

C3

100

Icu=35            Ics=22

C4

100

Icu=35            Ics=22

3. Operation conditions

1. Ambient temperature: the maximum temperature is +40? and the lowest temperature is -5?. The average temperature in 24 hours should be less than +35?.

2.The relative humidity of ambient air should be less than 50% when the highest temperature is +40?. The higher relative humidity is allowed at a lower temperature, for example, when the temperature is +20?, the relative humidity can be 90%. Dewing may happen accidentally due to the change of temperature.

3. Altitude should be less than 2000m.

4. Earthquake magnitude should be less than 8.

5. The place should be free from serious contamination, chemical corrosion, and strong vibration.

4. Dimensions

Height   (mm)

Width(mm)

Depth(mm)

1000-1700

500-800

300-400

5. Ordering Instruction

Orderer should offer the following technical document:

1. All types of products include main circuit plan No. and auxiliary circuit plan No.

2. Main circuit system combination sequence drawing

3. Auxiliary circuit electric scheme

4. Cabinet elements list

5. Setting parameters such as voltage, current and time

6. Other requirements not in accordance with a normal use


Send your message to this supplier
To:  

Shaanxi XD HI-TECH Medium-Low Voltage Apparatus Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  
  
You May Like
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
China Mainland Favorites
Transaction Level:

* Quantity:

You May Like