GCS-Type Low Voltage Withdrawable Electrical Control Switchgear/Board/Panel

  • Description
Product Detail

1. General

GCS-type Low voltage withdrawable electrical control switchgear can be applied to power plants, substations, petrochemical industry, industrial and mining enterprises as power supply, power distribution, motor control center, electric heater current limit and reactive compensation for the low-voltage distribution system.

This LV switchboard also can be used in low voltage power control center and motor control center of power plants with large unit capacity and large-scale petrochemical enterprises, for the reason of satisfaction of computers connection.

?  This withdrawable switchgear is designed as either three-phase four-wire type or three-phase five-wire type;

?  Each functional compartment is isolated relatively, and compartment effects are relatively independent;

?  The design of cable format makes upper and lower cables in/out, solve the problems existed in an old traditional product;

?  The number of functional units is determined by the standard modulus, they can be used in any combination as needed; the drawers with the same function can be interchanged conveniently.

2.  Model definition

    GCS MODE DEFINITION.jpg

 3.  Installation dimensions

Table of Outline and Installation Dimension         

A×B(mm)

C×D(mm)

GCS-TG-400×800

250×756

GCS-TG-600×800

450×756

GCS-TG-400×1000

250×956

GCS-TG-600×1000

450×956

GCS-TG-800×800

650×756

GCS-TG-800×1000

650×956

GCS-TG-800×600

650×956

GCS-TG-1000×600

850×556

GCS-TG-1000×800

850×756

GCS-TG-1000×1000

850×956

 Installation Dimension Diagram

Installation dimension diagram.jpg                  

Installation instruction of power receiving cabinet and contact cabinet

installation diagram of power receiving cabinet and contact cabinet.jpg

Figure 1 installation diagram of power receiving cabinet and contact cabinet

Common   cabinet No.

A

B

C

D

Remark

GCS-TG1010-4

1000

1000

850

956

Contact cabinet

GCS-TG0810-4

800

1000

650

956

Power   receiving cabinet

GCS-TG0808-4

800

800

650

756

Power   receiving cabinet

GCS-TG0608-4

600

800

450

756

Power   receiving cabine

PC cabinet installation instruction

 PC cabinet installation diagram.jpg

 Figure 2 PC cabinet installation diagram

Common   cabinet No.

A

B

C

D

E

F×G

GCS-TG1010-2

1000

1000

850

956

60

400×400

GCS-TG0810-2

800

1000

650

956

160

200×400

GCS-TG1008-2

1000

800

850

756

60

400×400

GCS-TG0808-2

800

800

650

756

160

200×400

 MCC cabinet installation instruction

 MCC cabinet installation diagram.jpg

 

Figure 3 MCC cabinet installation diagram

Common cabinet No.

A

B

C

D

E

F×G

GCS-TG1006-1

1000

600

850

556

60

400×350

GCS-TG0806-1

800

600

650

556

160

200×350

4. Main Basic Technical Parameters of Electrical Control Panel

Rated Voltage of   Main Power(∨)

AC 380(400)?(660)

Rated Voltage of   Auxiliary Power(∨)

AC 220?380(400) DC 110?220

Rated   Frequency(Hz)

50(60)

Rated   Insulation Voltage(∨)

660(1000)

Rated   Current(A)

Level Bus

≤4000

vertical   Bus(MCC)

1000

Bus   Rated Short-time Withstand Voltage(kA/s)

50?80

Bus   Rated Peak Withstand Current(kA/0.1s)

105?176

Protection Level

IP3X?IP4X

5. Operational Environment

1.The ambient temperature should be -5?-40?. The average temperature should be less than 35? in 24 hours. If exceeds, decrease capacity to operate according to the actual condition.

2. Used in indoor, and the altitude should be less than 2000m.

3. The relative humidity should be less than 50% when the highest temperature is 40?. Higher humidity is allowed when the temperature is low. For example, when the temperature is 20?,humidity is 90%. Dewing condition should also be considered due to the change of temperature.

4. The inclination with vertical plane should be less than 5% when install device and the whole set of cabinets should be leveled.

5. The device should be installed at the place where there is no serious vibration, impact and erosion of elements.

6. If the user has special requirements, coordinate with manufacturer.

6.  Ordering Instruction

Orderer should offer the following technical document:

1. All types of products include main circuit plan No. and auxiliary circuit plan No.

2. Main circuit system combination sequence drawing

3. Auxiliary circuit electric scheme

4. Cabinet elements list

5. Setting parameters such as voltage, current and time

6. Other requirements not in accordance with a normal use

7. Certificates

Send your message to this supplier
To:  

Shaanxi XD HI-TECH Medium-Low Voltage Apparatus Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  
  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
China Mainland Favorites
Transaction Level:

* Quantity:

You May Like