Product Detail
10kwh home/industry storage system
1. System Summary
10kwh home/industry storage system use grid system, include about inverter, lithium ion battery pack, battery BMS system, power switch, and information display parts, etc. Home/industry storage system can provide stabilized rate and constant voltage AC electric, such as servers, display power, medical equipment, home electric equipment, industry equipment, etc. When the AC grid normally running, storage system could let the home loading to connect with AC grid, and also can support the solar PV to charging the battery which inside of the system; When the AC grid have some accidents, the system will start the contravariant function, it will transfer the DC current from li ion battery to AC and connect the home loading.
2. Application frame
3. The specification of 10kwh home/industry storage system
Model (KWH) | 10 |
Inverter model (KW) | 5 |
Solar Controller (W) | 5000 |
Charger (A) | 40 |
Voltage of Battery pack(VDC) | 51.2 |
Capacity of battery (Ah) | 100 |
Weight (KG) | 125 |
System AC input (VAC) | 110/220 grid |
Inverter AC output (VAC) | 110/220 |
The voltage wave of inverter output | Pure sine wave |
The output rate of inverter | 50Hz±0.3Hz/ 60Hz±0.3Hz (Options) |
Noise (dB?1m) | ?60dB |
Running environment Temperature/humidity | -10~45?/0-90% |
Storage environment Temperature/humidity | -20~55?/0-90% |
Water proof | IP20 |
4. The specification of solar inverter
Solar inverter Specification | ||
Power specification | 10Kw | |
Specification of DC input | ||
Nominal voltage specification | DC48-AC220V | DC48-AC110V |
Working voltage Range (Normal working battery voltage) | 40V-64V (DC 48V power supply) | |
Low voltage warning | 42.0Vdc ±1.2Vdc (DC 48V power supply) | |
Low voltage and outage | 40.0Vdc ±1.2Vdc (DC 48V power supply) | |
Low voltage recovery | 48.0Vdc ±0.3Vdc (DC 48V power supply) | |
High voltage warning and outage | 64.0Vdc ±1.2Vdc (DC 48V power supply) | |
High voltage recovery | 62.0Vdc ±1.2Vdc (DC 48V power supply) | |
Contravariant Rate | =90% | |
DC first mode, | 44Vdc ±1.2Vdc (DC 48V power supply) | |
DC first mode, turn to gird supply, battery low voltage recovery | 54.0Vdc ±1.2Vdc (DC 48V power supply) | |
Specification of AC input | ||
Nominal voltage specification | 220VAC system | 110VAC system |
The voltage wave of input | Sine wave(grid) | Sine wave(grid) |
Nominal input voltage | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac |
Low voltage off point | 180Vac±4% | 85Vac±4% |
Low voltage recovery | 195Vac±4% | 90Vac±4% |
High voltage off point | 260Vac±4% | 135Vac±4% |
High voltage recovery | 255Vac±4% | 130Vac±4% |
Grid charging rule | Constant current charging?Constant voltage charging? | |
| ||
Grid supply rate | =98% |
Transfer time (AC to DC) | ?4ms | ||
Transfer time (DC to AC) | ?8ms | ||
AC output specification | |||
Nominal output voltage (V) | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac | |
Output voltage Range | ±10% rms | ||
Nominal output rate (Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | ||
Power Factor | 1.0 | ||
The wave of output | Pure sine wave | ||
THD | =3% ( loading) | ||
Over loading protect (SMPS load) | (110%<loading <125%)±10% :15 minuets later, off the output voltage | ||
| (125%<loading <150%)±10% :1 minuet later, off the output voltage | ||
| (loading >150%)±10% :20 seconds later, off the output voltage | ||
| Other instructions | ||
Continuous running time | Could be continuous running | ||
Normally start expand in vain | =Nominal power×2.5% | ||
Saving mode expand in vain | =6w | ||
Safety certificate | CE(EN62040-1) EMC:EN62040-2 C2, | ||
Communication port | RS232/RS485 | ||
Cooling | With fans | ||
Noise (dB?1 meter) | <60dB | ||
Using environment temperature (?) | -10~+45 | ||
Storage environment temperature (?) | -20~+55 | ||
Using environment humidity | 0-95% humidity | ||
Using altitude (m) | =5000 | ||
Display mode | LED light+ LCD display | ||
Warning model | Buzzer sound warning | ||
Protect function | Low voltage protect, High voltage protect, higher temperature protect, short circuit protect, leak electricity protect, Over current protect, over loading protect, low voltage recovery, high voltage recovery, intelligent temperature-control, accident warning; | ||
Water proof | IP20/ It is could be customized | ||
Specs of solar discharging and charging controller | |||
Specification | 48V100A | ||
Nominal Power (W) | 5000 | ||
Nominal charging current (A) | 100 | ||
Nominal DC voltage (V) | 48V | ||
PV Max Voltage (V) | <100 | ||
PV Max power (W) | 5000 | ||
Over charging protect voltage of battery (V) | 58.4 | ||
Over charging recovery voltage of battery (V) | 58.0 | ||
Constant charging voltage of battery (V) | 54.0 | ||
Over discharging warning voltage of battery (V) | 40 | ||
Protect function | Protect opposite charging in the night, Solar connect opposite. | ||
Control mode | PWM/MPPT | ||
Any other instructions |
|
The specs of Charger | |
Model | 2~5 KW |
DC voltage | 48V |
Charging current | 30A~100A |
The size of breaker | 20A~120A |
The size of breaker | 130A |
Charging voltage | According the specs of battery |
Charging short circuit protect | Breaker protect |
Charging rule | Constant current charging?Constant voltage charging?Float charging |
Charging period transfer | ? constant current charging stage: AC current input, the charger will run at the maximum constant current until the constant voltage phase. |
5. The specs of BMS board
Item | Options | Item | Options |
BMS working voltage range | 40~58.4V | BMS working | <3W |
BMS working temperature | -20~65? | BMS working humidity range | 5~90 |
Single cell voltage test range | 0~5V | Voltage test accuracy of one series cell | ±10mV |
Single cell voltage test rate | =10mS | Total voltage test channel | 1 |
Total voltage test accuracy | 0.5% FSR | Total voltage test range | 50~1000V |
Temperature test accuracy | ±1? | Temperature test range | -40~125? |
Insulator detection period | =10ms | Current test accuracy | <±1% FSR |
|
| SOC estimate accuracy | 5% |
|
| Balance mode | passivity |
6. Product picture (It is could be customizable.)
7.Home / Industrial Energy Storage System Functional Description
7.1 Features
? Overload capacity can be as high as rated power (300% for 20 seconds).;
? Inverter adopts low static current design, energy saving mode will reduce no-load loss period detection (3 seconds detection period) / 3W (30 seconds detection period), priority mode using maximum battery power, with different protection, battery low voltage cut out points can be set manually.
? Inverter adopts 4th-order intelligent charge design with power factor correction function, charging efficiency is higher.
? There is a 15-second delay before the AC restore conversion is completed, protecting the load from running stably (when the AC input is a generator).
? Mains and battery 10 ms conversion time to ensure the continuity of power; optional mains voltage range (184-253Vac or 154-253Vac) depending on the load type.
? The maximum rated charging current up to 90A, 0-100% adjustable.?
? Battery / mains priority mode setting switch; status display module, a variety of alarm fault indication, easy operation and maintenance.
? Battery overcharge, over discharge, high temperature, low temperature, over-current protection function, automatically shut off the battery pack output when a serious fault.
? Batteries single cell balancing function, balanced way for the passive balance, the equilibrium current of about 100mA, battery cells to maintain consistency.
? Battery pack insulation testing, storage system battery pack insulation alarm, to prevent leakage caused by a security incident.
? Battery thermal management function, the battery temperature is high, start the fan to complete the heat exchange, reducing the battery temperature.
? Battery pack power management function, when the battery voltage is lower than 40V, the battery pack is stopped so power supply, into the zero power mode.
? Battery pack real-time information data display function, the battery pack SOC, protection status, charge and discharge current, cell voltage, battery temperature and other information can be displayed on the LCD screen for user inquiries.
7.2External communication and program control
Energy storage system with external communication and programmable RS485, RS232 communication interface, can be used for energy storage systems and peripherals in real-time communication, data interaction. Communication speed 250Kbps or 500Kbps, communication protocol can be customized according to customer requirements.
- Solar Panels Ar Coating Photovoltaic Glass 1 Pieces / (Min. Order)
- Solar Garden Tempered Glass 1 Pieces / (Min. Order)
- Cooling Water Unit For Wide-format UV Printer 1 Pieces / (Min. Order)
- Boiler Feed Water Pump 1 Pieces / (Min. Order)
- Four Columnar Non-standard Booster Press 1 Pieces / (Min. Order)
- 16 Dots Large Character Inkjet Printer 1 Pieces / (Min. Order)
- Boil Water Heating Pipe 1 Pieces / (Min. Order)
- Boil Water Heating Pipe 1 Pieces / (Min. Order)
- Boil Water Heating Pipe 1 Pieces / (Min. Order)
- Glycol Salt Water Screw Chiller (-45°C) 1 Pieces / (Min. Order)
- Corrugated Paper Box 1 Pieces / (Min. Order)
- Circular Plate And Frame Filter Press 1 Pieces / (Min. Order)
- Cold Water Chiller Double 1 Pieces / (Min. Order)
- Luxury Wooden Hanger For Clothes 1 Pieces / (Min. Order)
- Swivel PU Leather Counter Chair 1 Pieces / (Min. Order)
- Color Changed Speaker Table Lamp 1 Pieces / (Min. Order)
- Steel Jacket Heat Preservation Pipes 1 Pieces / (Min. Order)
- Indoor Wall Decorative Leather Panels 1 Pieces / (Min. Order)
- Wholesale Water Base Square Flag 3m 5m 7m 1 Pieces / (Min. Order)
- Wholesale Water Base Square Flag 3m/ 5m/ 7m 1 Pieces / (Min. Order)