Emerson Rosemont Mont 8711 Electromagnetic Flowmeter Sensor

  • Description
Product Detail


The design of Ross Mont 8711 gripping sensor 8711 type gripper sensor has no flange design, making it an economical, compact and lightweight alternative to flange type electromagnetic flowmeter. Each 8711 - attached adjustment ring can center the sensor in the process pipe, making it easier to install. * light, easy to install sensors, suitable for a variety of common flow measurement * offers a variety of caliber and electrode materials, to meet various needs * your design cost-effective performance and the advantage of Monte Ross * 8711 non flange structure, size and weight of the smallest * from 0.15 to 8 inches (4 and 200 mm) of various caliber * ETFE lining provides a variety of sensor electrode materials available, suitable for measuring volume accuracy for most of the liquid sensor for * ETFE lining lining material to obtain FDA certification standard applications 8711 accuracy in Monte Ross flow range 13:1 ratio has reached as high as 0.15%, the ratio of 40:1 flow range is 0.25% 0.15-8 in diameter in (4-200 mm) ETFE, 316L stainless steel lining materials, PTFE and PFA electrode materials of nickel alloy, platinum, tantalum, titanium, the Please consult the materials he ASME B16.5 Class 150-300 flange rating manufacturer DIN PN 10-40 interchangeability and all E series transmitter compatibility with traditional transmitter Ross Monte 8700 series electromagnetic flowmeter series provides comprehensive lining and electrode material, suitable for almost any conductive liquid application. Ross Mont electromagnetic flowmeter has the advantages of measuring all kinds of flow and not affected by the change of density, temperature, pressure and viscosity.

The first step: flow sensor type application note precision option caliber coil driving power supply 8705 standard process design 0.25% standard 0.15% high 15 - 900 mm 0.5 - 36 in. pulsed DC 8711 compact, lightweight 0.25% standard 0.15% high 4 - 200 mm 0.15 - 8 in. pulsed DC 8721 dedicated to food and beverage and Life Sciences, after 3-A and EHEDG 0.5% standard certification 0.25% high 15-100 mm 0.5 - 4 in. DC 8707 P&P, M&M pulse slurry flow and noisy application best 0.5% standard 0.25% high 80 - 900 mm 3 - 36 in. large signal pulse DC

The second step is lining material selection, lining annotation, temperature range, type and caliber PFA (polyperfluoroalkoxy) best fluoropolymer, excellent chemical and abrasion resistance. It is suitable for any application. -20 to 350 degrees F (-29 to 177 degree C) flange type 15-350 mm 0.5 - 14 in. holding 4-8 mm 0.15 - 0.3 in. PTFE (PTFE) better fluoropolymer is more cost-effective than PFA. The anti - chemical property is excellent, but the wear resistance is worse than that of PFA. -20 to 350 degrees F (-29 to 177 degree C) flange type 15-900 mm 0.5 - 36 in. holding 15-200 mm 0.5 - 8 in. ETFE (ethyl polytetrafluoroethylene), good fluoropolymer anti chemical and wear resistance similar to PTFE, but the highest temperature is low and more expensive. -20 to 300 degrees F (-29 to 149 degree C) flange type 15-400 mm 0.5 - 16 in. holding 15-200 mm 0.5 - 8 in. polyester paint is usually applied to clear water (no chemicals). The slurry with small particles has a wear resistance. 0 to 140 degrees F (-18 to 60 C) flange 15-900 mm 0.5 - 36 in. chloroprene rubber is usually suitable for fresh water and sea water. The slurry with small particles has a wear resistance. 0 to 185 degrees F (-18 to 85 degrees C) flange type 80-1800 mm* 1.5 - 72 in. natural rubber is usually suitable for ore slurry, which has abrasion resistance for larger residues. 0 to 158 degrees F (-18 to 70 C) flange 80-900 mm 1.5 - 36 in.

The third step: the type of electrode and the type of material selection electrode apply the design of annotated button type standard electrode. It is suitable for most applications, especially the application of wear and tear. It has good resistance to the coating and can be improved by properly adjusting the size of the flow sensor. Bullet in the coating became the concern and there is no solid material occasion. Bullet electrode should not be used in corrosive or slurry applications, because the particles will lead to the increase of electrode process noise. The electrode material is used to annotate 316L stainless steel standard electrode material. It is compatible with most low concentration water based applications. Avoid the use of stainless steel in high concentration of acid applications. Nickel alloy 276 is used in the medium to high concentration acid applications that are unavailable for stainless steel. Used in the application of high chloride content, such as sea water. Platinum (80% platinum, 20% iridium) is an ideal choice for liquid applications in pulp and paper industries. It is also the ideal alternative electrode selection that covers almost all kinds of applications in the factory. It is compatible with almost every process fluid. Tantalum is an ideal choice for the measurement of high concentration of acid, hydrochloric acid and hydrofluoric acid. Titanium is an ideal choice for high concentration corrosion (alkali) applications such as sodium hydroxide and potassium hydroxide.

The fourth step: choose the transmitter type annotation Precision Power Options user interface protocol LOI 8732 integrated or split type installation of 0.25% high standard 0.15% AC / DC HART & the Foundation field bus, LOI optical switch or only display 8712 split wall mounted 0.25% standard 0.15% AC / DC high global HART special LOI 8712 big button signal split wall mounted. It is only compatible with type 8707 sensor. 0.5% standard 0.25% 115V AC HART special button LOI

The fifth step: diagnosis and enhance the function of the type annotations applicability criteria for the diagnosis of transmitter hardware fault; transmitter software fault; fault sensor coil; all ATC E series transmitter D1 high precision option (0.15%) type 8732 and type 8712 AX enhanced DI/DO capacity of 8732 and 8712 HART/FF DA1 / D01 diagnostic kit includes: grounding and wiring fault detection high process noise detection. Type 8732 and type 8712 DA2 / D02 diagnostic kit includes: 8714i built-in calibration of type 8732 and type 8712

Send your message to this supplier
To:  

Suga Industrial Equipment Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  
  
You May Like
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
China Mainland Favorites
Transaction Level:

* Quantity: