Cold Room Air Cooler
-
Min Order
1
-
Product Unit
Pieces
-
Origin
China Mainland
-
Payment
- Contact Now Start Order
- Favorites Share
- Description
Product Detail
DL, DD and DJ series cold room air cooler are made of copper tube stamping, aluminum fin two stamping, high heat transfer efficiency, moisture proof, low temperature, strong wind, low noise, smooth and reliable operation. The electric heating frosting system is made of stainless steel tube and finned heating tube directly into the interior. The thawing time is short and effective. The shell is made of high quality steel plate, and the spray process is corrosion resistant, the appearance is smooth, beautiful and universal.
DL, DD and DJ series rooftop suspended air coolers can be matched with condensers of different refrigerating capacity, and can be used for refrigerating rooms at different temperatures. The DL series is suitable for storage at 0 C temperature. Frozen storage can be used for fruits and vegetables, eggs and other DD series, which is suitable for cold storage at -18 degrees C, for storing meat, fish and fish and other frozen foods. DJ series is suitable for -23 C frozen meat and aquatic products.
DJ series unit radiator / radiator refrigeration unit is suitable for low temperature -25 degrees, with the following characteristics:
1. high quality competitive evaporative air cooler, air cooling evaporator
2. design of high efficiency coiler: small spiral copper tube
3, new wave fin: aluminum alloy, aluminized plate, magnesium aluminum alloy material. 3, a new type of shell design
4 options: aluminized zinc plate, electrostatic brush plate and 304 stainless steel plate
5. fan motor: external rotor motor with high efficiency and low power.
Model | Capacity (kW) | areas (m2) | Fan(380V) | Electrical heater (220V) (Kw) | Into tube (mm) | Back tube (mm) | |||
Power (W) | Air-flow (m3/h) | Diameter (mm) | |||||||
DJ-0.8/5 | 0.8 | 5 | 90 | 1*1700 | 300 | 0.7 | 0.7 | 12 | 16 |
DJ-1.3/8 | 1.3 | 8 | 2*90 | 2*1700 | 300 | 0.7 | 0.7 | 12 | 16 |
DJ-1.8/10 | 1.8 | 10 | 2*90 | 2*1700 | 300 | 0.8 | 0.8 | 12 | 19 |
DJ-2.1/15 | 2.1 | 15 | 2*120 | 2*2290 | 350 | 1.6 | 0.8 | 12 | 19 |
DJ-4.0/20 | 4.0 | 20 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 |
DJ-6.0/30 | 6.0 | 30 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 |
DJ-8.0/40 | 8.0 | 40 | 2*250 | 2*4950 | 450 | 6.0 | 1.2 | 19 | 30 |
DJ-11/55 | 11.0 | 55 | 2*250 | 2*4950 | 450 | 6.0 | 1.2 | 19 | 30 |
DJ-13/70 | 13.0 | 70 | 3*250 | 3*4950 | 450 | 8.0 | 1.6 | 19 | 38 |
DJ-16/85 | 16.0 | 85 | 3*250 | 3*4950 | 450 | 10.0 | 2.0 | 19 | 38 |
DJ-18.8/100 | 18.8 | 100 | 4*250 | 4*4950 | 450 | 11.0 | 2.2 | 25 | 45 |
DJ-21.6/115 | 21.6 | 115 | 4*250 | 4*4950 | 450 | 12.5 | 2.5 | 25 | 45 |
DJ-23.9/140 | 23.9 | 140 | 2*1500 | 2*10000 | 600 | 13.6 | 1.7 | 25 | 50 |
DJ-29.0/170 | 29.0 | 170 | 3*1500 | 3*10000 | 600 | 16.0 | 2.0 | 25 | 50 |
DJ-35.9/210 | 35.9 | 210 | 3*1500 | 3*10000 | 600 | 19.2 | 2.4 | 25 | 50 |
Model | Capacity (kW) | areas (m2) | Fan(380V) | Electrical heater | Into tube (mm) | Back tube (mm) | |||
Power (W) | Air-flow (m3/h) | Diameter (mm) | 220v(Kw) | ||||||
DD-1.4/7 | 1.4 | 7 | 90 | 1*1710 | 300 | 0.5 | 0.5 | 12 | 16 |
DD-2.4/12 | 2.4 | 12 | 2*90 | 2*1700 | 300 | 0.7 | 0.7 | 12 | 16 |
DD-3.0/15 | 3.0 | 15 | 2*90 | 2*1700 | 300 | 0.8 | 0.8 | 12 | 19 |
DD-4.0/22 | 4.0 | 22 | 2*120 | 2*2200 | 300 | 1.6 | 0.8 | 12 | 19 |
DD-6.0/30 | 6.0 | 30 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 |
DD-8.0/40 | 8.0 | 40 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 |
DD-12/60 | 12.0 | 60 | 2*250 | 2*4950 | 500 | 6.0 | 1.2 | 19 | 30 |
DD-16/80 | 16.0 | 80 | 2*250 | 2*4950 | 500 | 6.0 | 1.2 | 19 | 30 |
DD-20/100 | 20.0 | 100 | 3*250 | 3*4950 | 500 | 8.0 | 1.6 | 19 | 38 |
DD-24/120 | 24.0 | 120 | 3*250 | 3*4950 | 500 | 10.0 | 2.0 | 19 | 38 |
DD-28.0/140 | 28.0 | 140 | 4*250 | 4*4950 | 500 | 11.0 | 2.2 | 25 | 45 |
DD-32/160 | 32.0 | 160 | 4*250 | 4*4950 | 500 | 12.5 | 2.5 | 25 | 45 |
DD-37.4/200 | 37.4 | 200 | 2*1500 | 2*10000 | 600 | 13.6 | 1.7 | 25 | 50 |
DD-46.8/250 | 46.8 | 250 | 3*1500 | 3*10000 | 600 | 16.0 | 2.0 | 25 | 50 |
DD-56.2/310 | 56.2 | 310 | 3*1500 | 3*10000 | 600 | 19.2 | 2.4 | 25 | 50 |
Model | Ref. capacity (kw) | Cooling area (m²) | Space of fins | Fan | Defrost heater | |||||||
Qty | Dia.(mm) | Air volume(m3) | Pessure(pa) | Power (nxW) | Power supply | Coil (kw) | Catchment (kw) | Power supply | ||||
DL-2.1/10 | 2.1 | 10 | 4.5 | 1 | 300 | 1700 | 98 | 90 | 220V/380V 50Hz 1PH/3PH | 0.6 | 0.3 | 220V 50HZ 1PH |
DL-3.1/15 | 3.1 | 15 | 2 | 300 | 2x1700 | 98 | 2x90 | 0.9 | 0.6 | |||
DL-4.2/20 | 4.2 | 20 | 2 | 300 | 2x1700 | 98 | 2x90 | 0.9 | 0.6 | |||
DL-5.2/25 | 5.2 | 25 | 2 | 350 | 2x2200 | 98 | 2x140 | 380V 50HZ 3PH | 1.2 | 0.6 | ||
DL-8.2/40 | 8.2 | 40 | 2 | 400 | 2x3400 | 118 | 2x180 | 1.5 | 0.6 | |||
DL-11.5/55 | 11.5 | 55 | 2 | 400 | 2x3400 | 118 | 2x180 | 2.1 | 0.6 | |||
DL-16.7/80 | 16.7 | 80 | 2 | 500 | 2x6000 | 167 | 2x550 | 3.0 | 0.6 | |||
DL-22.0/105 | 22.0 | 105 | 2 | 500 | 2x6000 | 167 | 2x550 | 4.2 | 0.6 | |||
DL-25.8/125 | 25.8 | 125 | 3 | 500 | 3x6000 | 167 | 3x550 | 4.8 | 0.8 | |||
DL-35.6/160 | 33.6 | 160 | 3 | 500 | 3x6000 | 167 | 3x550 | 6.0 | 0.8 | |||
DL-38.7/185 | 38.7 | 185 | 4 | 500 | 4x6000 | 167 | 4x550 | 7.5 | 1 | |||
DL-44.0/210 | 44.0 | 210 | 4 | 500 | 4x6000 | 167 | 4x550 | 8.0 | 1 | |||
DL-52.9/260 | 52.9 | 260 | 2 | 600 | 2x10000 | 200 | 2x1100 | 10.0 | 2 | |||
DL-67.2/330 | 67.2 | 330 | 3 | 600 | 3x10000 | 200 | 3x1100 | 12.0 | 2 | |||
DL-83.4/410 | 83.4 | 410 | 3 | 600 | 3x10000 | 200 | 3x1100 | 14.0 | 2.6 |
- Gold Rich 1 Pieces / (Min. Order)
- Column And Booms 1 Pieces / (Min. Order)
- Clean Room 1 Pieces / (Min. Order)
- Comb Row 1 Pieces / (Min. Order)
- Customised VR Box 1 Pieces / (Min. Order)
- Cold Room Unit Cooler 1 Pieces / (Min. Order)
- Urumqi Cold Room 1 Pieces / (Min. Order)
- Cold Room Pallet 1 Pieces / (Min. Order)
- 10m³ Cold Room for Fish 1 Pieces / (Min. Order)
- Hola Loop 1 Pieces / (Min. Order)
- Soft Play Room 1 Pieces / (Min. Order)