  • Description
Product Detail

Jinhua Gafle is one of the leading refrigerant gas r407 manufacturers and suppliers in China, providing with the products free sample, welcome to wholesale our low price and customized bulk r407c made in China and check the quotation with our factory.

Applications include residential and commercial air conditioning systems, non-flooded evaporator chillers, and some commercial refrigeration systems. Since R-407C has similar properties to R-22, it is possible (with modifications) to use it in the same equipment designed for R-22 today.

R-407C can be used to retrofit existing R-22 systems in positive displacement, direct expansion refrigeration, and air conditioning equipment.

R-407C should not be used in centrifugal chillers or other equipment that uses a flooded evaporator due, 

to its high temperature glide.

Retrofit Procedure:

1. Establish baseline performance. Note the oil type in use and any system operating data (if system is operating properly). Check for existing leaks and identify any needed repairs.

2. Recover the existing refrigerant charge (DO NOT vent to atmosphere). Weigh the amount of refrigerant removed.

3. Drain existing oil from the compressor sump, suction line accumulators, etc. Record the amount of oil removed. Add an equivalent amount of OEM recommended POE oil.

4. Recharge the system with the recovered R-22 charge and run the system (at least 1 hour) to circulate the new lubricant.

5. Recover the R-22 charge again and check the residual oil content of the lubricant. The amount of the original lubricant in the POE must be less than 5%. 

6. Repeat steps 3 – 5, as needed, until the required oil purity level is reached. Once the oil flushes are completed,standard maintenance should be conducted (i.e. filter-drier change, leak repairs).

7. Evacuate the system (less than 500 microns) and ensure it maintains a vacuum. If vacuum is lost, it may indicate that leaks are present in the system.

8. Charge system with R-407C refrigerant. Remove refrigerant as liquid only from cylinder. The initial charge weight should be approximately 90% of the standard charge for R-22, charging up to 95% if necessary.

9. Adjust TXV set point and/or refrigerant charge to achieve the desired superheat. Low side 

pressure control settings may also need to be adjusted.

10. Monitor oil level in the compressor. If necessary, adjust oil amount to attain normal operating Specifications          

1.R407C of all specifications 

2.OEM is accepted 

3.Purity99.8% 

4.Certifications of 

SGS/ROSH/PONY/ISO9001/ISO14001/ISO1694 

Physical properties

Molecular formula


Mmolecular weight

86.20

Boiling point 101.3KPa(°C)

-43.80

Freezing point 101.3KPa (°C)

-

Density 30°C(kg/m3)

1129.30

Critical temperature (°C)

87.30

Critical pressure (MPa)

4.63

ODP

0.00

GWP

1700.00

Purity

=99.8%

Water content

=0.001%

Acidity

=0.00001%

Evaporation residue

=0.01%

Chloride content

=0.0001%

Appearance

Colorless and clear

Odor

Odorless

Packing specifications:

1,Non-refillable cylinder: 30lbs/11.3kg, CE Recycle cylinders

2,Refillable cylinder: 400L, 800L, 926L, 1000L.

3,ISO-Tank.

5,OEM is accept

6.DOT/CE/SGS/KGS approved.

Company show:


Send your message to this supplier
To:  

Jinhua Gafle Auto Maintenance Supplies Plant

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  
  
You May Like
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
China Mainland Favorites
Transaction Level:

* Quantity:

You May Like