Kubota Soundproof Genset 7 To 38 KVA 60HZ

  • Description
Product Detail

If you are checking kubota soundproof genset 7 to 38 kva 60hz prices, price list, and cost online, please feel free to contact Power-Mall Electricity Equipment, we are one of the leading China kubota soundproof genset 7 to 38 kva 60hz manufacturers and suppliers, and also a professional company equipped with productive factory, welcome to buy high quality products for sale from us.

Kubota Series Diesel Generator set 60HZ

Output Range:7~38KVA

Kubota’s largest yet super quiet, heavy-duty type 4 pole generator series.

The special enclosure with noise absorbing duct, over sized muffler.

Extra-long air cleaner hose, and quieter cooling fan all add up to its quiet performance.


Unit design,manufacture and acceptance in accordance with IEC34-1,IEC34-5,IEC34-6,JEC114,JEC139 and JEC146 international standard. The unit output power definition in accordance with ISO8528,ISO3046-1,DIN6271 and BS EN60034 NEMA international standard etc.

Kubota Diesel Genset Silent Type--60HZ

Genset Model

Prime Power

Standby Power

Kubota Engine

Elmor Alternator

kVA

kVA

Engine Model

Alternator Model

PM7.5KE6DE3S

7.5

8.3

D905-E2BG

EMA164A

PM10KE6DE3S

10

11

D1105-E2BG

EMA164A

PM13.5KE6DE3S

13.5

14.9

V1505-E2BG

EMA164B

PM15KE6DE3S

15

16.5

D1703-E2BG

EMA164C

PM21KE6DE3S

21

23.4

V2203-E2BG

EMA184E

PM26KE6DE3S

26

28.3

V2003T0E2BG

EMA184E

PM34.4KE6DE3S

34.4

37.8

V3300-E2BG

EMA184F

PM43PE6DE3S

43

46.8

V3300T-E2BG

EMA184H


Dependable generation


Direct Coupled

The generator and the engine are direct-coupled to ensure a more reliable power supply with minimum power loss.

Excellent Load Characteristics

Solid-state voltage regulation maintains excellent stability (less than 5%) during changing load conditions. Quick response automatically provides stable power to sensitive equipment. 

Clean Emissions

Diesel engines selected to power the heavy-duty SQ series produce far less soot, HC and CO emissions thanks to Kubota's original E-TVCS combustion. All engines for the North American and European markets have passed the latest EPA and Europe's Emissions Regulations.

Ease of Operation

Improved Enclosure with a Noise Absorbing Duct

Noise within the generator unit has been lowered by improving the noise reduction enclosure and by adding a new noise absorbing duct with 3 air intake holes.

Improved Enclosure with a Noise Absorbing Duct

Noise within the generator unit has been lowered by improving the noise reduction enclosure and by adding a new noise absorbing duct with 3 air intake holes. 

Over-Sized Muffler

The over-sized muffler has lowered the sound level.

Quieter Cooling Fan

Kubota not only reduced fan related noise with this larger-diameter, slower-speed fan, but also maintained the same cooling effect as one running at normal speed.

Reduced Air Inlet Noise

A longer air filter inlet hose is used to keep the low frequency noise down.

Base Mounted Fuel Tank

The SQ series is equipped with large capacity bottom mounted fuel tanks to prevent fuel spills inside the enclosure. The locking fuel cap is placed to avoid damage and simplify refueling.

Compact and Easy to Transport

The advanced design and superior engineering minimizes both space and weight.

Transportability is improved with slots on each side of the machine for safe forklift truck transportation.


Carefree Maintenance:

Easy One Side Maintenance

Engine oil and coolant drain extensions are provided to ease regularly scheduled maintenance. Oil gauge, filter, oil replacement port, fuel filter, water reserve tank, battery and air filter are all located on one side for quick inspection and maintenance. 

Locking Control Panel Door

Shields instrument panel from the elements and permits observation of all key functions without opening the door. 

Automatic Air-Bleeding

Every time the engine key is turned ON, air is automatically purged from the fuel system.

Automatic Start System

Wiring and space have been provided as standard equipment for standby applications.


Increased Safety

Designed with Safety in Mind

The fully covered load center houses all the outlets, compression terminals, and circuit breakers. To prevent inadvertent contact with the terminals, the receptacles are divided in a separate section.

Safety Door Interlocks

Safety door interlocks automatically shut down the engine if the load center doors are opened during operation. For safe, unattended operation, even the maintenance doors are equipped with safety interlocks

Safe Enclosure

Large, removable doors feature heavy-duty steel hinges and recessed locking door latches safeguard against unauthorized use, allow safe, unattended operation and easy maintenance.


Please send E-mail to sales@power-mall.cn for latest favorable quotation.


 

Send your message to this supplier
To:  

Jiangsu Power-Mall Electricity Equipment Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  
  
You May Like
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
China Mainland Favorites
Transaction Level:

* Quantity:

You May Like